English Español עברית
Gavish GreenLine

MC10 Controller

 

Outputs
16 outputs of 24 VAC

Analog inputs
Up to 8 Analog inputs
4-20 mA, 1-5 VDC
Resolution: 8 bits (0.4%)

Digital inputs/counters
Up to 16 digital inputs/counters
12-24 VDC

Analog outputs
None

Outputs fuse protection
Main fuse – 5 A

Led display
Led on each output

Panel display
Separate controller, communicates using RS485

Communication
One communication port, RS485 protocol

Program storage
20 K Eprom - burn only once, replace when full

Memory
256 variables
250 set points

Messaging protocol
Gavish 

 